Bard Lubricath Drainage Bag Foley Tray with Tamper-Evident Seal and Anti-Reflux Chamber

Bard Lubricath Drainage Bag Foley Tray with Tamper-Evident Seal and Anti-Reflux Chamber

Brand/Manufacturer: BARD INC
Hpfy stores Save
  • Prescription required

Bard Lubricath Drainage Bag Foley Tray features a latex foley catheter pre-connected to a drainage bag and includes the Uro-Prep tray which contains all materials necessary for aseptic catheter insertion. Foley catheter assists in smoother insertion and provides enhanced patient comfort through the hydrogel coating which has unique ability to absorb fluid, thus creating a hydrophilic cushion between the catheter surface and the urethra.

Bard Lubricath Drainage Bag Foley Tray Includes:

  • Bardex Lubricath latex foley catheter with 5cc balloon
  • 2000ml drainage bag with anti-reflux chamber
  • Uro-Prep tray

Item # Desc Pkg Price
899616 With 16FR Catheter Each
$22.89
$15.99
899616 With 16FR Catheter 10/Case
$199.99
$139.99

Lubricath Drainage Bag Foley Tray Highlights

  • Uro-Prep tray contents:
  • - Drape
    - Underpad
    - Powder-free, latex-free exam gloves
    - Forceps
    - Rayon balls 
    - Pre-filled inflation syringe
    - Lubricant
    - Povidone-iodine solution
    - Specimen container and label

Lubricath Drainage Bag Foley Tray Benefits

  • Sterile
  • Latex, allows atraumatic insertion for enhanced patient comfort
  • Hydrogel coating of foley catheter maintains its integrity throughout the course of use, resulting in less trauma upon removal
  • Tamper-Evident Seal provides a clear indication of system opening, a key area of bacterial entrance to the urinary tract
  • EZ-Lok sampling port eliminates the risk of needlestick injuries and allows for needle-free aspiration
  • Unique domed design of the anti-reflux chamber prevents urine reflux from the urine drain bag back into the drainage tube
  • Drainage bag features bag vent to assist in drainage

More On Bard Lubricath Drainage Bag Foley Tray

EZ-Lok Guidelines for Drainage:

  • Occlude drainage tubing a minimum of 3" below the sampling port by kinking the tubing until urine is visible under the access site
  • Swab surface of Bard EZ-Lok Sampling Port with antiseptic wipe 
  • Using aseptic technique, position the syringe in the center of the sampling port. The syringe should be held perpendicular to the surface of the sampling port (at approximately 80o-100o angle), press the syringe firmly and twist gently to access the sampling port
  • Slowly aspirate urine sample into syringe and remove from sample port
  • Unkink tubing and transfer urine specimen into specimen cup, discard syringe according to hospital protocol
  • Follow established hospital protocol for specimen labeling and transport to lab


Inflation/Deflation Guidelines:

  • Proper Catheter Inflation:
    - Ensure that the Bard Foley catheter balloon is positioned well within the patients baldder. 
    - Slowly, with a gentle, constant force, inflate the Bard Foley catheter balloon with the volume prescribed on the package. Note that a 5cc balloon must be inflated with between 9cc and 10cc of sterile water.
    - Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties.
  • Catheter Deflation:
    - Select a luer slip syringe
    - Slide the plunger of the syringe up and down the barrel of the syringe several times to "loosen it up"
    - Compress the plunger all the way and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel
    - Gently insert syringe in the catheter valve
    - Do not use more force than is required to make the syringe "stick" in the valve
    - Allow the pressure within the balloon to force the plunger back and fill the syringe with water
    - If the user notice slow or no deflation, re-seat the syringe gently, once again, allow the balloon to deflate slowly on its own
    - If the balloon does not deflate, reposition the patient
    - Ensure that the catheter is not in traction - the proximal end of the catheter is not compressed within the bladder neck
    - Ensure that urine flows freely
    - Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe
    - If the balloon still fails to deflate, apply very gentle, slow aspiration, aspiration that is too rapid or too forceful, may cause the inflation lumen within the Foley catheter to collapse
    - If permitted by hospital protocol, the valve arm may be severed
    - If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close