Bard StatLock MultiPurpose Stabilization Device

Bard StatLock MultiPurpose Stabilization Device

Brand/Manufacturer: BARD INC
Hpfy stores Save
  • Latex Free

Bard StatLock MultiPurpose Stabilization Device is designed to reduce potential complications associated with tape or suture securement. It features tricot anchor pads with nylon filaments for securing chest tubes. StatLock catheter securement devices help to improve patient outcomes, quality of care and economic efficiency.

StatLock MultiPurpose Adult Catheter Stabilization Device Highlights:

  • Eliminate suture securement 
  • Improve patient comfort
  • Prevent needlestick risks

Item # Desc Pkg Price
MP0120 Long 5" Filament, Tricot Anchor Pad, Adult Each
$37.25
$29.48
MP0120 Long 5" Filament, Tricot Anchor Pad, Adult 25/Pack
$918.68
$734.94

StatLock MultiPurpose Adult Catheter Stabilization Device

  • Bard StatLock MultiPurpose Adult Catheter Stabilization Device features nylon filaments used for needle-free stabilization
  • Offers needle-free securement of chest tubes, sheath introducers, drainage devices and more through the use of nylon strands that grip the tubing. 
  • Long filaments (5") are ideal for securing chest tubes, drainage tubes and other, large, medical tubes
  • Short filaments (2.5") provides an ideal method for securing winged central venous and other catheters
  • Crescent anchor pad consists of closed cell foam with two short strand nylon filaments for securing chest tubes
  • Effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies
  • Provides superlative results in promoting healthcare worker safety and patient satisfaction

  • Indications For Use: 
    - Compatible for medical tubes and catheters

More On StatLock MultiPurpose Adult Catheter Stabilization Device

Contraindications:

  • Known tape or adhesive allergies
  • Known sensitivity to benzoin (Zinc Oxide PICC Neonatal Universal)


Warning and Precautions:

 

  • Do not use the device where loss of adherence could occur, such as with a confused patient, unattended access device, diaphoretic or non-adherent skin, or when the access device is not monitored daily
  • Observe universal blood and body fluid precautions and infection control procedures, during the device application and removal
  • Suture the device pad to skin if necessary or deemed necessary
  • Avoid the device contact with alcohol or acetone, both can weaken bonding of components and the device pad adherence
  • Minimize catheter manipulation during device application and removal
  • Remove oil and moisturizer from targeted skin area
  • Pad adherence and catheter/tube position should be routinely inspected
  • Orient the device so arrows point toward the catheter tip
  • Should be replaced every 7 days
  • Luer-lock connector must be used to secure venous and arterial catheters
  • Always apply the adhesive strip to central venous and arterial catheters at or near the insertion site when using the device
  • This is a single use device
  • Reuse or repackaging may create a risk of patient or user infection, compromise the structural integrity or essential material and design characteristics of the device, which may lead to device failure, or lead to injury, illness or death of the patent
  • Do not re-sterilize
  • The sterility of the single use device is not guaranteed following re-sterilization because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infection complications
  • Re-sterilization may compromise the structural integrity, essential material or design characteristics and may lead to an unpredictable loss of functionality or device failure
  • Do not use alcohol or acetone containing products on pre-term infants

 

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close