Bard StatLock Universal Plus Stabilization Device

Bard StatLock Universal Plus Stabilization Device

Brand/Manufacturer: BARD INC
Hpfy stores Save
  • Latex Free

Bard StatLock Universal Plus Stabilization Device sets the new standard of excellence for suture-free stabilization of biliary and nephrostomy percutaneous drainage and peritoneal lavage catheters. It comes in different sizes to fit virtually all percutaneous drainage catheters. Advanced technologies combine with the StatLock Stabilization Device design sophistication to deliver skin-safe, suture-free, releasable stabilization of even the most lubricious catheters.

StatLock Universal Plus Stabilization Device Highlights

  • Releasable device clamp and anchor pad
  • Minimizes complications associated with suturing
  • Reduces catheter tip micromotion
  • Maintains IV catheter placement better than others
  • Greater adhesive strength

 

Item # Desc Pkg Price
VUPD1214 Large, For 12Fr to 14Fr Each
$37.05
$26.49

Features of StatLock Universal Plus Catheter Stabilization Device

  • Bard StatLock Universal Plus Stabilization Device improves patient comfort and safety by eliminating the need to secure catheters with suture
  • Universal plus stabilization device reduces catheter tip micromotion better than tape and provide greater stability over time
  • Bard stabilization device maintains IV catheter placement better than others
  • Effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies
  • FSA approved and latex free
  • Prevents needlestick risks
  • Effective alternative to tape

 

What to buy with StatLock Universal Plus Stabilization Device

 

How to Use Bard StatLock Universal Plus Stabilization Device?

  • Prepare the targeted securement site with alcohol or chloraprep solution to degrease skin. Then apply skin protectant solution for enhanced adherence and skin protection. Allow to dry completely for 10 to 15 seconds.
  • Wipe catheter with remaining skin protectant (so it is wet for insertion into the StatLock device retainer).
    Note: Always secure catheter to the StatLock device retainer before placing pad on the skin.
  • Bring the StatLock deivice anchor pad into position. Stabilize the catheter between fingers and then double tug catheter to stretch-fit into retainer.
  • Close lid.
  • Peel away the StatLock device paper backing one side at a time.
  • Place on the skin.

How to Remove Bard StatLock Universal Plus Stabilization Device?

  • Open the StatLock device retainer by pressing tab and lifting lid.
  • Carefully lift catheter from retainer.
  • First lift edge of anchor pad using 3 to 4 alcohol pads.
  • Then continue to stroke undersurface of pad with alcohol to dissolve adhesive anchor pad away from skin.
    Note: Do not pull or force pad to remove.

Warnings and Precautions of Bard Medical StatLock Universal Plus Stabilization Device

  • Do not use the StatLock stabilization device where loss of adherence could occur, such as with a confused patient, unattended access device, diaphoretic or non-adherent skin, or when the access device is not monitored daily.
  • Observe universal blood and body fluid precautions and infection control procedures, during the StatLock stabilization device application and removal.
  • Suture the StatLock stabilization device pad to skin if necessary or deemed necessary.
  • Avoid the StatLock stabilization device contact with alcohol or acetone, both can weaken bonding of components and the StatLock stabilization device pad adherence.
  • Minimize catheter manipulation during StatLock stabilization device application and removal.
  • Remove oil and moisturizer from targeted skin area.
  • The StatLock stabilization device pad adherence and catheter/tube position should be routinely inspected.
  • Orient the StatLock stabilization device so arrows point toward the catheter tip.
  • The StatLock stabilization device should be replaced every 7 days.
  • A StatLock stabilization device luer-lock connector must be used to secure venous and arterial catheters.
  • Always apply the adhesive strip to central venous and arterial catheters at or near the insertion site when using a StatLock stabilization device.
  • This is a single-use device. Reuse/and or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patent.
  • Do not re-sterilize. The sterility of the single-use device is not guaranteed following re-sterilization because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infection complications. Re-sterilization may compromise the structural integrity, essential material and/or design characteristics and may lead to an unpredictable loss of functionality and/or device failure.

 

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close