BD SAF-T Intima Closed IV Catheter System

BD SAF-T Intima Closed IV Catheter System

Brand/Manufacturer: BECTON DICKINSON
Hpfy stores Save
  • Prescription required
  • FSA Approved

BD Saf-T-Intima closed IV catheter System is made of clinically superior BD Vialon biomaterial that offers passive needle shielding to provide the highest degree of safety while providing both clinical and economic benefits. The integrated system provides added protection from blood and bloodborne pathogens. The unique, telescoping safety shield covers the needle after use to help protect against accidental needlesticks injuries.

Item # Desc Pkg Price
383312 24 G x 0.75", With Removable PRN Adapter Each
$11.25
$8.04
383312 24 G x 0.75", With Removable PRN Adapter 25/Pack
$255.75
$202.88
383312 24 G x 0.75", With Removable PRN Adapter 200/Case
$252.05
$199.89
383313 24 G x 0.75", With Y Adapter Each
$11.25
$8.04
383313 24 G x 0.75", With Y Adapter 25/Pack
$255.75
$202.88
383322 22 G x 0.75", With Removable PRN Adapter Each
$11.25
$8.04
383322 22 G x 0.75", With Removable PRN Adapter 25/Pack
$252.05
$199.89
383322 22 G x 0.75", With Removable PRN Adapter 200/Case
$1999.99
$1599.99
383323 22 G x 0.75", With Y Adapter Each
$11.45
$7.83
383323 22 G x 0.75", With Y Adapter 25/Pack
$244.05
$193.50
383323 22 G x 0.75", With Y Adapter 200/Case
$1933.89
$1547.11

Features

  • BD Saf-T-Intima Closed IV Catheter System features a removable PRN adapter that lets the user connect with his choice of needleless injection system or infusion line
  • The multipurpose design features an integral extension set with a slide clamp
  • A unique "Y" adapter can preconnect the BD Saf-T-Intima integrated IV catheter and create a closed catheter system for a virtually bloodless insertion
  • Flexible, textured wings provide confident catheter control and a broad base for a secure, low-profile tapedown and optimal patient comfort
  • The pre-attached extension tubing offers a closed system, ensuring a virtually bloodless venipuncture
  • The "Y" adapter allows for prepriming and flushing during venipuncture

More Information

  • Needle Removal:
    - To remove the needle, stabilize catheter wings
    - Grasp white shield and pull in a straight continuous motion
    - Shield will come off, exposing the adapter
  • Securement:
    - Secure catheter and apply sterile dressing according to policy and procedure

  • Things to Remember:
    - Do not bend the needle prior to insertion
    - Never reinsert needle into the catheter as this could shear the catheter
    - Do not use scissors at or near the insertion site
    - Aseptic technique and proper skin preparation of the site are essential
    - Discard the needle in the nearest sharps collector. Follow your institutions policy for safe disposal of all medical waste

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close