Bard Lubri-Sil Two-Way I.C. Infection Control Foley Catheter With 30cc Balloon Capacity

Bard Lubri-Sil Two-Way I.C. Infection Control Foley Catheter With 30cc Balloon Capacity

Brand/Manufacturer: BARD INC
Hpfy stores Save
  • Prescription required
  • FSA Approved
  • Latex Free

Bard Lubri-Sil Two-Way I.C. Infection Control Foley Catheter With 30cc Balloon Capacity incorporates a technologically-advanced formulation consisting of bacti-guard silver alloy coating and hydrogel which reduces adhesion of the bacteria most commonly associated with catheter-associated urinary tract infections (CAUTIs). The coating on this catheter is designed to minimize biofilm formation and enhance patient comfort.

Lubri-Sil Two-Way I.C. Infection Control Foley Catheter Features:

  • Tip: Round 
  • Lubrication: Silver hydrogel coating 
  • Material: Silicone, latex-free

Item # Desc Pkg Price
1768SI16 16FR Each
$36.64
$29.31
1768SI18 18FR Each
$29.29
$23.43
1768SI20 20FR Each
$38.99
$30.89
1768SI22 22FR Each
$33.67
$26.93
1768SI24 24FR Each
$29.29
$23.43

Features

Inflation/Deflation Guidelines

  • Proper Catheter Inflation:
    Ensure that the Bard Foley catheter balloon is positioned well within the patients bladder.
    - Slowly, with a gentle, constant force, inflate the Bard Foley catheter balloon with the volume prescribed on the package. Note that a 5cc balloon must be inflated with between 9cc and 10cc of sterile water.
    - Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties.
  • Catheter Deflation:
    -
    Select a luer slip syringe
    - Slide the plunger of the syringe up and down the barrel of the syringe several times to "loosen it up"
    - Compress the plunger all the way and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel
    - Gently insert syringe in the catheter valve
    - Do not use more force than is required to make the syringe "stick" in the valve
    - Allow the pressure within the balloon to force the plunger back and fill the syringe with water
    - If you notice slow or no deflation, re-seat the syringe gently, once again, allow the balloon to deflate slowly on its own
    - If the balloon does not deflate, reposition the patient
    - Ensure that the catheter is not in traction - the proximal end of the catheter is not compressed within the bladder neck
    - Ensure that urine flows freely
    - Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe
    - If the balloon still fails to deflate, apply very gentle, slow aspiration, aspiration that is too rapid or too forceful, may cause the inflation lumen within the Foley catheter to collapse
    - If permitted by hospital protocol, the valve arm may be severed
    - If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol

Specification

Particulars Specifications
Catheter Tip Standard Tip
Catheter Material Silicone
Gender Unisex
Catheter Coating Hydrogel Coated
Catheter Style Coated Catheters
Catheter French Size 18FR,20FR
Ballon Size (CC) 30cc

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close