Bard Silastic 2-Way Standard Specialty Foley Catheter With 5cc Balloon Capacity

Bard Silastic 2-Way Standard Specialty Foley Catheter With 5cc Balloon Capacity

Brand/Manufacturer: BARD INC
Hpfy stores Save
  • Prescription required
  • FSA Approved

Item 33618, 33620 is backorder and will be available to purchase once it is back in stock.

Bard Silastic 2-Way Standard Specialty Foley Catheter With 5cc Balloon Capacity has smooth, non-stick silicone exterior coating which reduces calcification build-up. It maximizes stiffness without compromising flexibility. Bard Silastic Catheter comes with firm, but flexible, latex-based construction with large drainage lumen. It features short round tip with two opposing drainage eyes.

What does Silastic Two-Way Standard Catheter Includes?

  • Firm, but flexible, latex-based construction
  • Large drainage lumen
  • Short round tip
  • Two opposing drainage eyes

Item # Desc Pkg Price
33614 14FR Each
$22.07
$17.65
33614 14FR 5/Pack
$106.10
$84.88
33614 14FR 10/Case
$220.85
$176.68
33616 16FR Each
$21.93
$17.54
33616 16FR 5/Pack
$98.05
$78.44
33616 16FR 10/Case
$196.09
$156.87
33618 18FR Each
$20.80
$16.64
33618 18FR 5/Pack
$103.70
$82.96
33624 24FR Each
$22.07
$17.65
33624 24FR 5/Pack
$110.49
$88.39
33624 24FR 10/Case
$220.85
$176.68

Silastic 2-Way Foley Catheter Features

What to buy with 2-Way Standard Foley Catheter?


How Inflation And Deflation take place in Foley Catheter?

Catheter Inflation:
  • Ensure that the Bard Foley catheter balloon is positioned well within the patients bladder. Slowly, with a gentle, constant force, inflate the Bard Foley catheter balloon with the volume prescribed on the package
  • Note that the 5cc balloon must be inflated with between 9cc to 10cc of sterile water
  • Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties
  • Using fluid other than sterile water may cause the balloon not to empty properly, especially after long dwell times

  • Catheter Deflation:
    • Select a luer slip syringe
    • Slide the plunger of the syringe up and down the barrel of the syringe several times to loosen it up
    • Compress the plunger all the way and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel
    • Gently insert the syringe in the catheter valve.
    • Do not use more force than is required to make the syringe stick in the valve
    • Allow the pressure within the balloon to force the plunger back and fill the syringe with water
    • If you notice slow or no deflation, re-seat the syringe gently. Once again, allow the balloon to deflate slowly on its own
    • If the balloon does not deflate, reposition the patient
    • Ensure that the catheter is not in traction, the proximal end of the catheter is not compressed within the bladder neck
    • Ensure that urine flows freely
    • Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe as described above
    • If the balloon stills fails to deflate, apply very gentle slow aspiration. Aspiration that is too rapid, or too forceful, may cause the inflation lumen within the Foley catheter to collapse
    • If permitted by hospital protocol, the valve arm may be severed
    • If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol.

  • Silastic Standard Catheter Specifications

    Catheter TipShort Round
    Catheter MaterialLatex

    Gender

    Unisex

    Catheter Coatingsilicone exterior coating

    Catheter Style

    Coated Catheters

    Catheter French Size

    14FR,16FR,18FR,20FR,22FR,24FR

    Ballon Size (CC)

    5cc

    Drainage Eyes

    Two Opposing Eyes


    Customer Reviews

    Please enter your and your friends email address below.
    Fields marked with * are compulsory
     
    *
    *
    *
    *


    Submit Cancel
    The selected product information has been successfully emailed to your friend.

    Thank you for using www.shopcatheters.com

    Close