Bard Two Way Uncoated Silicone Foley Catheter With 30cc Balloon Capacity

Bard Two Way Uncoated Silicone Foley Catheter With 30cc Balloon Capacity

Brand/Manufacturer: BARD INC
Hpfy stores Save
  • Prescription required
  • FSA Approved
  • Latex Free

Bard Two Way Uncoated Silicone Foley Catheter With 30cc Balloon Capacity enhances safety and comfort for latex sensitive patients. The latex-free catheter surface resists encrustation and exceptional balloon strength helps prevents rupture and premature deflation. This 100 percent silicone foley catheter features round tip with two opposing eyes.

Item # Desc Pkg Price
166816 16FR Each
$12.85
$9.05
166816 16FR 12/Case
$135.79
$108.63
166818 18FR Each
$12.85
$9.05
166818 18FR 12/Case
$135.79
$108.63
166820 20FR Each
$12.85
$9.05
166820 20FR 12/Case
$135.79
$108.63
166822 22FR Each
$12.85
$9.05
166822 22FR 12/Case
$135.79
$108.63
166824 24FR Each
$12.85
$9.05
166824 24FR 12/Case
$135.79
$108.63

Bard 2-Way Foley Catheter Features

  • Reduces friction and improves patient comfort
  • Latex-free
  • Sterile
  • For single patient use

Inflation/Deflation Guidelines

  • Catheter Inflation:
    - Ensure that the Bard Foley catheter balloon is positioned well within the patients bladder. Slowly, with a gentle, constant force, inflate the Bard Foley catheter balloon with the volume prescribed on the package
    - Note that the 5cc balloon must be inflated with between 9cc to 10cc of sterile water
    - Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties
    - Using fluid other than sterile water may cause the balloon not to empty properly, especially after long dwell times

  • Catheter Deflation:
    - Select a luer slip syringe
    - Slide the plunger of the syringe up and down the barrel of the syringe several times to loosen it up
    - Compress the plunger all the way and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel
    - Gently insert the syringe in the catheter valve
    - Do not use more force than is required to make the syringe stick in the valve
    - Allow the pressure within the balloon to force the plunger back and fill the syringe with water
    - If you notice slow or no deflation, re-seat the syringe gently. Once again, allow the balloon to deflate slowly on its own
    - If the balloon does not deflate, reposition the patient.
    - Ensure that the catheter is not in traction, the proximal end of the catheter is not compressed within the bladder neck
    - Ensure that urine flows freely
    - Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe as described above
    - If the balloon stills fails to deflate, apply very gentle slow aspiration. Aspiration that is too rapid, or too forceful, may cause the inflation lumen within the Foley catheter to collapse
    - If permitted by hospital protocol, the valve arm may be severed
    - If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol

Specification

ParticularsSpecifications
Catheter TipRound Tip
Catheter MaterialSilicone
GenderUnisex
Catheter StyleUncoated Catheters
Catheter French Size16FR, 18FR, 20FR,22FR
Ballon Size (CC)30cc
Drainage EyesTwo Opposing Eyes

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close